For Programmers: Free Programming Magazines  


Home > Archive > Cobol > December 2006 > COBOL/CICS/DB2 - COBOL for MVS and compile option DYNAM









You are viewing an archived Text-only version of the thread. To view this thread in it's original format and/or if you want to reply to this thread please [click here]

 

Author COBOL/CICS/DB2 - COBOL for MVS and compile option DYNAM
Andreas Lerch

2006-11-29, 6:55 pm

Hello all

System: z/OS and LE for MVS

Why is it possible to compile a COBOL/CICS/DB2 program with the=20
options:

NODYNAM . . . ?????

nowerdays thats not the state of the art, because:

IMS could be called dynamic
COBOL and ASSEMBLER could be called dynamic

why not inside of a CICS environment

I asked this question, because i mus used the same sources in two=20
environments:

DB2 Batch (IMS/DSN) - one compile and link
DB2 CICS - a second compile and link

i have to manage two sources inside a revision environment!!!

The first source could be compiled with the option: DYNAM for batch -=20=

and all calls are managed by COBOL and MVS

in CICS, the precompiler sets the COBOL options to NODANM. Therefore i=20=

need a second source to manage the environment. I must use the=20
CICS-link library to link the DSNHLI and i can NOT use the same module=20=

in IMS/TSO, because they need different HLI's: for IMS propagator=20
DSNHLI from IMS for DSN propagator DSNHLI from DB2.

I would link a DB2 module without a specific DSNHLI.......

Is DFHECI unable to be called dynamic? IMS module DFSLI000 could.

Why does DB2 precompiler generate calls like: CALL 'DSNHLI' USING=20
PLIST-x, instead of CALL DSNHLI USING PLIST-x, where DSNHLI ist=20
defined as a variable inside the working-storage section?

I am not pleased about this situation.

I hope, that you could follow my intention... :-)

i am not so stable in english

Einen schoenen Tag
Andreas Lerch



CG

2006-11-29, 6:55 pm

Andreas Lerch wrote:
> Hello all
>
> System: z/OS and LE for MVS
>
> Why is it possible to compile a COBOL/CICS/DB2 program with the
> options:
>
> NODYNAM . . . ?????
>
> nowerdays thats not the state of the art, because:
>
> IMS could be called dynamic
> COBOL and ASSEMBLER could be called dynamic
>
> why not inside of a CICS environment
>
> I asked this question, because i mus used the same sources in two
> environments:
>
> DB2 Batch (IMS/DSN) - one compile and link
> DB2 CICS - a second compile and link
>
> i have to manage two sources inside a revision environment!!!
>
> The first source could be compiled with the option: DYNAM for batch -
> and all calls are managed by COBOL and MVS
>
> in CICS, the precompiler sets the COBOL options to NODANM. Therefore i
> need a second source to manage the environment. I must use the
> CICS-link library to link the DSNHLI and i can NOT use the same module
> in IMS/TSO, because they need different HLI's: for IMS propagator
> DSNHLI from IMS for DSN propagator DSNHLI from DB2.
>
> I would link a DB2 module without a specific DSNHLI.......
>
> Is DFHECI unable to be called dynamic? IMS module DFSLI000 could.
>
> Why does DB2 precompiler generate calls like: CALL 'DSNHLI' USING
> PLIST-x, instead of CALL DSNHLI USING PLIST-x, where DSNHLI ist
> defined as a variable inside the working-storage section?
>
> I am not pleased about this situation.
>
> I hope, that you could follow my intention... :-)
>
> i am not so stable in english
>
> Einen schoenen Tag
> Andreas Lerch


Andreas,

I believe the short answer to this is:
1) Yes, all of the CICS interface components must be static CALLs.
That is why the preprocessor generates CALL 'literal' statements.
2) If you need to force your own programs to be dynamically called,
instead of depending on the DYNAM/NODYNAM option you should change your
calls to CALL data-name and assign the name of your routine to
data-name. This form of the CALL will always be dynamic no matter what
the setting of DYNAM/NODYNAM.

If you manage your programs and let the preprocessors manage theirs, all
should work out fine.

Good luck.
Carl

Clark F Morris

2006-11-29, 9:55 pm

On Wed, 29 Nov 2006 18:38:43 GMT, Andreas Lerch
<andreas.lerch@onlinehome.de> wrote:

>Hello all
>
>System: z/OS and LE for MVS
>
>Why is it possible to compile a COBOL/CICS/DB2 program with the
>options:
>
>NODYNAM . . . ?????


The reason is to force all CALL literal statements to bind the called
module to the COBOL program. This reduces overhead because a dynamic
call takes both more instructions on initial call as well as the
subsequent calls. This is important in a CICS environment where there
may be many transactions at the same time executing the program. Also
the cost of the initial call may be a higher percentage of overall
execution in a CICS environment. You can still dynamically call
modules by using CALL data-name which forces DYNAM for the specific
call. This can be more efficient than EXEC CICS LINK.
>
>nowerdays thats not the state of the art, because:
>
>IMS could be called dynamic
>COBOL and ASSEMBLER could be called dynamic
>
>why not inside of a CICS environment
>
>I asked this question, because i mus used the same sources in two
>environments:
>
>DB2 Batch (IMS/DSN) - one compile and link
>DB2 CICS - a second compile and link
>
>i have to manage two sources inside a revision environment!!!
>
>The first source could be compiled with the option: DYNAM for batch -
>and all calls are managed by COBOL and MVS
>
>in CICS, the precompiler sets the COBOL options to NODANM. Therefore i
>need a second source to manage the environment. I must use the
>CICS-link library to link the DSNHLI and i can NOT use the same module
>in IMS/TSO, because they need different HLI's: for IMS propagator
>DSNHLI from IMS for DSN propagator DSNHLI from DB2.
>
>I would link a DB2 module without a specific DSNHLI.......
>
>Is DFHECI unable to be called dynamic? IMS module DFSLI000 could.
>
>Why does DB2 precompiler generate calls like: CALL 'DSNHLI' USING
>PLIST-x, instead of CALL DSNHLI USING PLIST-x, where DSNHLI ist
>defined as a variable inside the working-storage section?
>
>I am not pleased about this situation.
>
>I hope, that you could follow my intention... :-)
>
>i am not so stable in english
>
>Einen schoenen Tag
>Andreas Lerch
>
>

Kelly Bert Manning

2006-11-29, 9:55 pm

Clark F Morris (cfmpublic@ns.sympatico.ca) writes:

> execution in a CICS environment. You can still dynamically call
> modules by using CALL data-name which forces DYNAM for the specific
> call. This can be more efficient than EXEC CICS LINK.


The advice we got during migration to LE in the early 1990s was that
EXEC CICS LINK or XCTL was 10 times the overhead of a COBOL DYNAMIC CALL.

Has that improved with later versions of CICS and Enterprise COBOL?

We had trouble getting DYNAMIC calls to work during a tuning exercise, so
we ended up using STATIC CALLS. LE had already increased developer familiarity
with using AMBLIST to see what was inside load modules and how to replace
particular CSECTs within a load module using the Linkage Editor. (I never
call it the binder because DB2 developers seem to get when I do
that)
Arnold Trembley

2006-11-30, 3:55 am



Kelly Bert Manning wrote:
> Clark F Morris (cfmpublic@ns.sympatico.ca) writes:
>
>
>
>
> The advice we got during migration to LE in the early 1990s was that
> EXEC CICS LINK or XCTL was 10 times the overhead of a COBOL DYNAMIC CALL.
>
> Has that improved with later versions of CICS and Enterprise COBOL?


I don't know if this has improved, but I believe it is still true that
it is much faster to transfer control from one CICS COBOL program to
another by a dynamic call, rather than an EXEC CICS LINK or EXEC CICS
XCTL.

But that really has no bearing on the original question. Every CICS
COBOL program must be compiled with the NODYNAM option, because each
EXEC CICS statement is translated into a CALL 'DFHEI1' USING <variable
parameter list>.

It is DFHEI1 that must be statically linked to your CICS COBOL program
in order to execute any CICS services. Remember, your COBOL program
is really executing as a subprogram of CICS, and it needs the DFHEI1
hook in order to connect to CICS.

>
> We had trouble getting DYNAMIC calls to work during a tuning exercise, so
> we ended up using STATIC CALLS.


Sorry to hear you had troubles. I've worked with CICS applications
that do it successfully, although I don't remember the details without
the source code in front of me. It's definitely possible to do.

With kindest regards,

--
http://arnold.trembley.home.att.net/

CG

2006-11-30, 3:55 am

Kelly Bert Manning wrote:
> Clark F Morris (cfmpublic@ns.sympatico.ca) writes:
>
>
> The advice we got during migration to LE in the early 1990s was that
> EXEC CICS LINK or XCTL was 10 times the overhead of a COBOL DYNAMIC CALL.
>
> Has that improved with later versions of CICS and Enterprise COBOL?


Dynamic CALLs via CALL data-name are still the recommended linkage
between user components.

>
> We had trouble getting DYNAMIC calls to work during a tuning exercise, so
> we ended up using STATIC CALLS. LE had already increased developer familiarity
> with using AMBLIST to see what was inside load modules and how to replace
> particular CSECTs within a load module using the Linkage Editor. (I never
> call it the binder because DB2 developers seem to get when I do
> that)

We have an automatic way to replace user components. Contact me
off-list if you want more info.

Carl
Andreas Lerch

2006-11-30, 6:55 pm

>
> The reason is to force all CALL literal statements to bind the called
> module to the COBOL program. This reduces overhead because a dynamic
> call takes both more instructions on initial call as well as the
> subsequent calls. This is important in a CICS environment where there
> may be many transactions at the same time executing the program. Also
> the cost of the initial call may be a higher percentage of overall
> execution in a CICS environment. You can still dynamically call
> modules by using CALL data-name which forces DYNAM for the specific
> call. This can be more efficient than EXEC CICS LINK.


I know this, and this is my problem. I have a little load inside CICS,
up to 500.000 transactions a day is the maximum. The avarage response
time is under 0,01 seconds (some heavy tasks may have more, buts less
than 1.000). I have no response problems since 10 or 15 years with
this application.

For CICS/DB2, IMS/DB2 i must have two identical sources and objects,
the only difference is PROGRAM ID. One for CICS and one for IMS...

All my other subroutines are called by literal, only DSN*-modules are
called by constant and only inside CICS.
------
If i have a mission critical application, i don't use HLL. I want to
reduce the maintenace overhead to manage two identical sources. If i
can use the same module in IMS and CICS, I can save money, but CICS
precompiler forces the COBOL compiler option to NODYNAM.

The proloque of a DB2-call is a sequence of CALL 'DSNADDR' USING ...,
CALL 'DSNADDR2' USING .. this could be static, it is used one time for
invocation. CALL DSNHLI USING could be a [0]CALL
WORKING-STORAGE-FIELD-DSNHLI USING ...
[0] This is what i want. Then I can save the time, to manage TWO ore
more Sources. This can reduce mistakes, by using the wrong
INCLUDE-libs for CICS. In the past I have to solve some Problems, that
the developer uses CICS link librarys in batch with
NODYNAM and DB2 link librarys inside CICS.

I must use:
CICS-DSNHLI inside CICS --> this is FORCED to NODYNAM by CICS
precompiler
IMS-DSNHLI inside IMS --> no change of my COBOL compile parms, I can
use DYNAM
DB2-DSNHLI inside RUN DSN --> no change of my COBOL compile parms, I
can use DYNAM

Thank you for your answer.

einen schoenen Tag
Andreas Lerch
Andreas Lerch

2006-11-30, 6:55 pm

>
> It is DFHEI1 that must be statically linked to your CICS COBOL program
> in order to execute any CICS services. Remember, your COBOL program
> is really executing as a subprogram of CICS, and it needs the DFHEI1
> hook in order to connect to CICS.
>

No - why - CBLTDLI uses the same code sequence and it must not called
static.

einen schoenen Tag
Andreas Lerch
Colin Campbell

2006-11-30, 6:55 pm

Hallo Andreas,
You state that your two programs are almost entirely common, except for
the CALL statements and compiler options, due to the restrictions of
CICS compared to IMS and DB2.

Have you looked into using COBOL's Compiler Directing Statements to
bring in the needed source code, and specify the needed compiler
options? You would still have two source programs, but those programs
would be mostly COPY statements, and would not change. The code that
you COPY into these programs would either be the same, with different
REPLACING strings on the COPY statements, or there would be some COPY
members that are unique to each environment (some for CICS, others for
IMS, etc.).

Then, when you change logic which is common to either environment, you
would only have one place to make the change -- in the COPY member.

CBL or PROCESS statements in the source code could help you with the
needed compiler options.

If your shop uses a Configuration Management tool (you mention a
"revision environment"), it should also be possible to control the
compile options inside that tool.
Colin

P.S.: Your English was just fine. One word I noticed, though, was
"nowerdays", which should be written "nowadays".
CG

2006-11-30, 6:55 pm

Andreas Lerch wrote:
> No - why - CBLTDLI uses the same code sequence and it must not called
> static.

One is CICS and one is IMS. Two totally different architectures that
just happen to have been made to co-exist.
Carl
Andreas Lerch

2006-12-01, 6:55 pm

On Thu, 30 Nov 2006 23:28:11 UTC, CG
<carl.gehr.RemoveThis@ThisToo.attglobal.net> wrote:

> Andreas Lerch wrote:
> One is CICS and one is IMS. Two totally different architectures that
> just happen to have been made to co-exist.
> Carl


Hello Carl

yes, you are right, I forgot this. Since 15 years i use the same code
in both environments CICS and Batch, with dynamic calls, so i forgot
this little difference. CICS and IMS have different DFSLI00......
Sorry

einen schoenen Tag
Andreas Lerch
Andreas Lerch

2006-12-01, 6:55 pm

On Thu, 30 Nov 2006 21:29:09 UTC, Colin Campbell
<cmcampb@adelphia.net> wrote:

Hello Colin

> Hallo Andreas,
> You state that your two programs are almost entirely common, except for
> the CALL statements and compiler options, due to the restrictions of
> CICS compared to IMS and DB2.


no - the CALL statements are identical only the compiler options are
different

> Have you looked into using COBOL's Compiler Directing Statements to
> bring in the needed source code, and specify the needed compiler
> options? You would still have two source programs, but those programs
> would be mostly COPY statements, and would not change. The code that
> you COPY into these programs would either be the same, with different
> REPLACING strings on the COPY statements, or there would be some COPY
> members that are unique to each environment (some for CICS, others for
> IMS, etc.).


the sequence is:
DB2 precompiler (batch and CICS) [0]
CICS precompiler (CICS only) [1]
LINK

[0] changes the EXEC SQL .. to CALL 'DSNxxx' using...
[1] changes all DYNAM to NODYNAM

> Then, when you change logic which is common to either environment, you
> would only have one place to make the change -- in the COPY member.


thats not a solution, it is a solution with COBOL-VS neither in an
area past COBOL-VS. If i have an indicator inside the calling
parameter, i can perform different code in CICS and batch --> see
GOOGLE with search <"Andreas Lerch" Language-Environment Cobol for
MVS&VM zOS 1.2> (without bracket), i don't know the message-id - sorry

> CBL or PROCESS statements in the source code could help you with the
> needed compiler options.


CICS precompiler forcec the CBL-statement to NODYNAM every other
directive is removed. see [1]

> If your shop uses a Configuration Management tool (you mention a
> "revision environment"), it should also be possible to control the
> compile options inside that tool.


we use a tool, but also se [1] .

Next w, i will try to connect IBM.

DB2-Team --> to answer the question: Which parameter can be used to
produce source-code like:
CALL Working-Storage-Field-DSN USING ..
instead of
CALL 'DSN....' USING

and CICS-TEAM --> to answer the question: Which reason is neccessary
to use NODYNAM in a past COBOL-VS area

i am not amused :-)

einen schoenen Tag
Andreas Lerch

> P.S.: Your English was just fine. One word I noticed, though, was
> "nowerdays", which should be written "nowadays".

ok - I will do my very best :-)